Skip to main content
  • Technical innovations
  • Open access
  • Published:

A safe and simple technique for nasogastric tube insertion in patients with thoracic esophageal cancer surgery

Abstract

Background

Risk factors for anastomotic leakage include local factors such as excessive tension across anastomosis and increased intraluminal pressure on the gastric conduit; therefore, we consider the placement of a nasogastric tube to be essential in reducing anastomotic leakage. In this study, we devised a safe and simple technique to place an NGT during an end-to-side, automatic circular-stapled esophagogastrostomy.

Methods

First, a 4-0 nylon thread is fixed in the narrow groove between the plastic and metal parts of the tip of the anvil head. After dissecting the esophagus, the tip of the NGT is guided out of the lumen of the cervical esophageal stump. The connecting nylon thread is applied to the anvil head with the tip of the NGT. The anvil head is inserted into the cervical esophageal stump, and a purse-string suture is performed on the esophageal stump to complete the anvil head placement. The main unit of the automated stapler is inserted through the tip of a reconstructed gastric conduit, and the stapler is subsequently fired and an end-to-side esophagogastrostomy is achieved. The main unit of the automated stapler is then pulled out from the gastric conduit, and the NGT comes out with the anvil head from the tip of the reconstructed gastric conduit. Subsequently, the nylon thread is cut. After creating an α-loop with the NGT outside of the lumen, the tip of the NGT is inserted into the gastric conduit along the lesser curvature toward the caudal side. Finally, the inlet of the automated stapler on the tip of the gastric conduit is closed with an automated linear stapler, and the esophagogastrostomy is completed.

Results

We utilized this technique in seven patients who underwent esophagectomy for esophageal cancer; smooth and safe placement of the NGT was accomplished in all cases.

Conclusion

Our technique of NGT placement is simple, safe, and feasible.

Background

Patients who require nasogastric tube (NGT) insertion for bowel decompression in the context of various pathological conditions are often encountered. NGT insertion following upper gastrointestinal surgery has been reported to be effective in preventing suture failure as a function of intestinal decompression, enhanced detection of postoperative bleeding, and prevention of aspiration pneumonia. However, complications such as misinsertion into the trachea, bleeding upon contact with the anastomotic site, and anastomotic leakage have also been reported with this insertion [1,2,3,4]. Anastomotic leakage, recurrent laryngeal nerve palsy, and pneumonia are the three major postoperative complications associated with esophagectomy for esophageal cancer, all of which are sometimes life-threatening. It is well known that the occurrence of these serious complications leads not only to prolonged hospitalization and deterioration of quality of life but also to exacerbation of the long-term prognosis of esophageal cancer [5, 6]. Recent studies have demonstrated that recurrent laryngeal nerve palsy can be avoided by surgical technique or targeted intraoperative monitoring of the nerve [7, 8]. In addition, perioperative, integrated multidisciplinary care of patients can help reduce the risk of developing postoperative pneumonia [9, 10]. Insufficient blood flow and excessive tension across the anastomosis, increased intraluminal pressure of the gastric conduit, structural changes associated with preoperative chemoradiotherapy, and invasive nature of esophageal surgery are contributing factors to the high incidence of anastomotic leakage after esophageal cancer surgery [11,12,13].

With an aim to maintain low intraluminal pressures in the regions of esophagogastric anastomoses, NGT was inserted for 5 days after esophageal cancer surgery at our institute. Some conditions such as cough, swallowing, and insufficient gastric evacuation increased the pressure on the anastomoses, which may lead to anastomotic leakage. Meanwhile, intraoperative insertion of an NGT after completing an esophagogastrostomy is complicated because it involves a blind maneuver, wherein the tip of the NGT may collide with the anastomosis and cause unexpected mechanical stimulation of the surgical site. Furthermore, upon NGT insertion into the gastric conduit, under endoscopic guidance, following completion of the esophagogastric anastomosis, further mechanical stimulation is exerted on the esophagogastric anastomotic site [14]. In relation to this, our study describes our safe and simple technique developed to place an NGT upon the conduct of an end-to-side, automatic, circular-stapled esophagogastrostomy.

Methods

At our institution, an end-to-side esophagogastrostomy with a narrow gastric conduit elevated via a posterior mediastinal route was performed at the level of the neck using an automatic circular stapler (CDH, Ethicon, Somerville, NJ, USA) in patients who underwent McKeown’s esophagectomy. In cases wherein an NGT could pass beyond the esophageal tumor, it was inserted into the stomach prior to induction of general anesthesia to prevent mask ventilation-related air retention in the alimentary tract until endotracheal intubation.

First, a 4-0 nylon thread was fixed in the narrow groove between the plastic and metal parts of the tip of the anvil head prior to performing an esophagogastric anastomosis (Fig. 1).

Fig. 1
figure 1

A 4-0 nylon thread is fixed in the narrow groove between the plastic and metal parts of the tip of the anvil head

When dissecting the esophagus, the tip of the NGT was moved to the oral side away from the dissection line, pushed back, and guided out of the lumen of the cervical esophageal stump that is to be anastomosed. After connecting the nylon thread applied on the anvil head with the tip of the NGT (Fig. 2), the anvil head was inserted into the cervical esophageal stump as the NGT was slowly and gently pulled out through the nose, and a purse-string suture was performed on the esophageal stump to complete the anvil head placement (Fig. 3). The main unit of the automated stapler was inserted through the tip of a reconstructed gastric conduit, and the trocar of the automated stapler was positioned in the planned anastomotic site and then joined to the anvil head (Fig. 4). The stapler was subsequently fired, and an end-to-side esophagogastrostomy was achieved. The main unit of the automated stapler was pulled out from the gastric conduit, and the NGT was removed with the anvil head beyond the anastomosis from the tip of the reconstructed gastric conduit (Fig. 5). Subsequently, the nylon thread was cut. After creating an α-loop with the NGT outside the lumen, the tip of the NGT was inserted into the gastric conduit along the lesser curvature toward the caudal side until the tip of the NGT traverses past the anastomotic segment under either visual or manual guidance (Fig. 6). Once the tip of the NGT had traversed caudally beyond the esophagogastric anastomosis, the NGT has almost no risk of exerting pressure on the anastomosis despite pushing the tube in/out through the nose.

Fig. 2
figure 2

The 4-0 nylon thread applied on the anvil head is connected to the tip of the NGT

Fig. 3
figure 3

The anvil head is inserted into the cervical esophageal stump as the NGT is slowly and gently pulled out through the nose

Fig. 4
figure 4

The trocar of the automated stapler is positioned in the planned anastomotic site on the greater curvature of the gastric conduit and joined to the anvil head

Fig. 5
figure 5

The main unit of the automated stapler is then pulled out from the gastric conduit, and the NGT comes out with the anvil head beyond the esophagogastric anastomosis

Fig. 6
figure 6

With creating an α-loop (white arrow) with the NGT outside of the lumen, the tip of the NGT is inserted into the gastric conduit along the lesser curvature

The inlet of the automated stapler on the tip of the gastric conduit was closed with an automated linear stapler (Fig. 7). The anastomosis was re-evaluated in multiple directions, and an air leak test was performed to complete the esophagogastrostomy.

Fig. 7
figure 7

The inlet of the automated stapler on the tip of the gastric conduit is closed with an automated linear stapler

Results

We used this technique in seven patients (six men and one woman) who underwent esophagectomy for esophageal cancer. All the patients had a preoperative histological diagnosis of esophageal squamous cell carcinoma, and their ages ranged from 61 to 79 years, with a median of 72 years. Five patients presented with a middle thoracic esophageal cancer and two with a lower esophageal cancer.

All the patients underwent McKeown’s esophagectomy. End-to-side esophagogastrostomy with a gastric conduit, which was elevated via the posterior mediastinal route, was performed at the level of the neck using a CDH circular stapler. Smooth and safe placement of the NGT was accomplished in all the patients without any technical difficulty or improper placement. Furthermore, no anastomotic leakage occurred in any patients.

Discussion

Esophageal cancer surgery is strongly associated with anastomotic leakage compared to other gastrointestinal surgeries. Risk factors for anastomotic leakage include systemic factors, such as increased age, poor nutritional status, and presence of comorbidities; local factors, such as increased intraluminal pressure in the gastrointestinal tract, impaired circulation, and infection; and specific factors associated with highly invasive esophageal surgery. Moreover, it is difficult to keep the anastomosis stable under stress caused due to activities resulting from the jittering motion caused by breathing, cardiac pumping, and swallowing. Circulatory disorders of the reconstructed organs strongly influence the risk of anastomotic leak, which must be addressed and resolved by esophageal surgeons [11,12,13].

There are two main methods of esophagogastric anastomosis: hand-sewn anastomosis and instrumental anastomosis. The instrumental anastomosis can be divided into end-to-side anastomosis using a circular stapler and end-to-end or side-to-side anastomosis using a linear stapler. We usually perform an end-to-side automatic circular-stapled esophagogastrostomy because it is simple and less susceptible to the influence of the surgeon’s skill level as compared to anastomoses using linear staplers. However, this method results in loss of the gastric wall structure in response to the size of the circular stapler, thereby impairing blood supply in the gastric conduit and resulting in reduced blood flow to the tip of the gastric conduit. In addition, the liner-stapled entry hole for the circular stapler becomes a blind stump, thus presenting a risk factor for anastomotic leakage. This portion is susceptible to the intraluminal pressure arising from the gastric conduit itself [15,16,17]. Therefore, we believe that NGT placement is essential in minimizing adverse events caused by both the esophagogastric anastomosis and the stump of the gastric conduit, which are associated with increased intragastric pressure from coughing and regurgitation of gastric juices and bile.

The key points of our technique to avoid an unexpected contact with the end-to-side, esophagogastric anastomosis when placing an NGT are as follows: (1) connection of an NGT to the anvil head using a nylon thread, (2) passage of the NGT through the esophagogastric anastomosis in the direction of the thread, (3) guidance of the NGT out of the gastric conduit from its tip and creation of an α-loop with the NGT outside of the gastric conduit, and (4) gentle manual reinsertion of the NGT along the lesser curvature until the tip of the NGT traverses past the anastomotic segment, preventing the gastric tube from returning to the oral side through the esophagogastric anastomosis. At this time, the creation of an α-loop with the NGT outside the gastric conduit enables relatively safer and easier placement of the NGT into the gastric conduit, as shown in Fig. 6.

Although we used the CDH stapler in this study, our technique can be applied using other automatic circular staplers such as the EEA stapler (Covidien, Minneapolis, MN, USA). Three small holes on the anvil head of the EEA stapler can be used to connect to an NGT using a 4-0 nylon thread.

Our study has some potential limitations, including a limited number of specific cases. Moreover, the incidence of anastomotic leakage has not been compared between this technique and the conventional method of blind insertion or insertion under endoscopic guidance. Furthermore, this technique may be used for intrathoracic anastomoses; however, the narrow intercostal space makes it difficult to insert the main unit of the automated stapler into the thoracic cavity. The author has never performed this procedure for intrathoracic anastomosis.

Although the utility of NGT placement in the postoperative management of esophageal surgery is still unclear and controversial [18,19,20], we hypothesize that decompression of the intragastric conduit using an NGT is helpful in decreasing postoperative complications such as anastomotic leakage and aspiration pneumonia associated with gastroesophageal reflux and delayed gastric emptying. Furthermore, it is useful for detecting these complications. Our technique of NGT placement is simple and safe and may contribute to reducing the associated mechanical forces exerted on the esophagogastric anastomosis and decreasing anastomosis-related complications.

Conclusions

Our technique of NGT placement during the performance of an end-to-side, automatic, circular-stapled esophagogastrostomy is a safe, simple, and feasible method.

Availability of data and materials

The datasets used and analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

NGT:

Nasogastric tube

References

  1. Pillai JB, Vegas A, Brister S. Thoracic complications of nasogastric tube: review of safe practice. Interact Cardiovasc Thorac Surg. 2005;4(5):429–33. https://doi.org/10.1510/icvts.2005.109488.

    Article  PubMed  Google Scholar 

  2. Sorokin R, Gottlieb JE. Enhancing patient safety during feeding-tube insertion: a review of more than 2000 insertions. JPEN J Parenter Enteral Nutr. 2006;30:440–5. https://doi.org/10.1177/0148607106030005440.

    Article  PubMed  Google Scholar 

  3. Roubenoff R, Ravich WJ. Pneumothorax due to nazogastric feeding tubes. Arch Intern Med. 1989;149:184–8. https://doi.org/10.1001/archinte.149.1.184.

    Article  CAS  PubMed  Google Scholar 

  4. Baskin WN. Acute complications associated with bedside placement of feeding tubes. Nutr Clin Pract. 2006;21(1):40–55. https://doi.org/10.1177/011542650602100140.

    Article  PubMed  Google Scholar 

  5. Saeki H, Tsutsumi S, Tajiri H, Yukaya T, Tsutsumi R, Nishimura S, et al. Prognostic significance of postoperative complications after curative resection for patients with esophageal squamous cell carcinoma. Ann Surg. 2017;265(3):527–33. https://doi.org/10.1097/SLA.0000000000001692.

    Article  PubMed  Google Scholar 

  6. Baba Y, Yoshida N, Shigaki H, Iwatsuki M, Miyamoto Y, Sakamoto Y, et al. Prognostic impact of postoperative complications in 502 patients with surgically resected esophageal squamous cell carcinoma: a retrospective single-institution study. Ann Surg. 2016;264(2):305–11. https://doi.org/10.1097/SLA.0000000000001510.

    Article  PubMed  Google Scholar 

  7. Yuda M, Nishikawa K, Takahashi K, Kurogochi T, Tanaka Y, Matsumoto A, et al. A strategy for using intraoperative nerve monitoring during esophagectomy to prevent recurrent laryngeal nerve palsy. Anticancer Res. 2018;38(3):1563–7. https://doi.org/10.21873/anticanres.12385.

    Article  PubMed  Google Scholar 

  8. Kanemura T, Miyata H, Yamasaki M, Makino T, Miyazaki Y, Takahashi T, et al. Usefulness of intraoperative nerve monitoring in esophageal cancer surgery in predicting recurrent laryngeal nerve palsy and its severity. Gen Thorac Cardiovasc Surg. 2019;67(12):1075–80. https://doi.org/10.1007/s11748-019-01107-5.

    Article  PubMed  Google Scholar 

  9. Shirakawa Y. Perioperative team cooperation in Okayama University Hospital. Nihon Geka Gakkai Zasshi. 2017;118(2):149–54.

    PubMed  Google Scholar 

  10. Shimoda A, Soh J, Ashiba T, Murata N, Fukuda T, Kobayashi M, et al. Cross-sectoral approach of a perioperative management center for general thoracic surgery. Kyobu Geka. 2016;69(1):20–4.

    PubMed  Google Scholar 

  11. Takeuchi H, Miyata H, Gotoh M, Kitagawa Y, Baba H, Kimura W, et al. A risk model for esophagectomy using data of 5354 patients included in a Japanese nationwide web-based database. Ann Surg. 2014;260:259–66. https://doi.org/10.1097/SLA.0000000000000644.

    Article  PubMed  Google Scholar 

  12. Schmidt HM, Gisbertz SS, Moons J, Rouvelas I, Kauppi J, Brown A, et al. Defining benchmarks for transthoracic esophagectomy: a multicenter analysis of total minimally invasive esophagectomy in low risk patients. Ann Surg. 2017;266(5):814–21. https://doi.org/10.1097/SLA.0000000000002445.

    Article  PubMed  Google Scholar 

  13. Seesing MFJ, Gisbertz SS, Goense L, van Hillegersberg R, Kroon HM, Lagarde SM, et al. A propensity score matched analysis of open versus minimally invasive transthoracic esophagectomy in the Netherlands. Ann Surg. 2017;266(5):839–46. https://doi.org/10.1097/SLA.0000000000002393.

    Article  PubMed  Google Scholar 

  14. Karagama YG, Lancaster JL, Karkanevatos A. Nasogastric tube insertion using flexible fibreoptic nasoendoscope. Hosp Med. 2001;62(6):336–7. https://doi.org/10.12968/hosp.2001.62.6.1587.

    Article  CAS  PubMed  Google Scholar 

  15. Sasaki K, Omoto I, Uchikado Y, Okumura H, Noda M, Tsuruda Y, et al. Comparison of greater curvature and lesser curvature circular-stapled esophagogastrostomy after esophagectomy in patients with esophageal cancer: a prospective randomized controlled trial. Surg Today. 2021;51(4):575–81. https://doi.org/10.1007/s00595-020-02147-8.

    Article  PubMed  Google Scholar 

  16. Deng XF, Liu QX, Zhou D, Min JX, Dai JG. Hand-sewn vs linearly stapled esophagogastric anastomosis for esophageal cancer: a meta-analysis. World J Gastroenterol. 2015;21(15):4757–64. https://doi.org/10.3748/wjg.v21.i15.4757.

    Article  PubMed  PubMed Central  Google Scholar 

  17. Tagkalos E, van der Sluis PC, Uzun E, Berlth F, Staubitz J, Gockel I, et al. The circular stapled esophagogastric anastomosis in esophagectomy: no differences in anastomotic insufficiency and stricture rates between the 25 mm and 28 mm circular stapler. J Gastrointest Surg. 2021. https://doi.org/10.1007/s11605-020-04895-x.

  18. Nelson R, Edwards S, Tse B. Prophylactic nasogastric decompression after abdominal surgery. Cochrane Database Syst Rev. 2007;2007(3):CD004929. https://doi.org/10.1002/14651858.CD004929.

    Article  PubMed Central  Google Scholar 

  19. Weijs TJ, Kumagai K, Berkelmans GH, Nieuwenhuijzen GA, Nilsson M, Luyer MD. Nasogastric decompression following esophagectomy: a systematic literature review and meta-analysis. Dis Esophagus. 2017;30(3):1–8. https://doi.org/10.1111/dote.12530.

    Article  PubMed  Google Scholar 

  20. Zhang C, Zhang M, Gong L, Wu W. The effect of early oral feeding after esophagectomy on the incidence of anastomotic leakage: an updated review. Postgrad Med. 2020;132(5):419–25. https://doi.org/10.1080/00325481.2020.1734342.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

None.

Funding

This study received no external sources of funding.

Author information

Authors and Affiliations

Authors

Contributions

NH was the lead author and surgeon for all of the patients. TM, KS, and YU were the co-surgeons of the cases. TY, RH, KT, and KI contributed patients and information on the patients. YT reviewed the paper and surgical technique. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Noriyuki Hirahara.

Ethics declarations

Ethics approval and consent to participate

This study was performed in line with the principles of the Declaration of Helsinki and the Japanese Ethical Guidelines for Clinical Studies. Approval was granted by the Shimane University Institutional Committee on Ethics. Written informed consent was obtained from all individual participants included in the study.

Consent for publication

Patients signed informed consent regarding publishing their data.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Hirahara, N., Matsubara, T., Kaji, S. et al. A safe and simple technique for nasogastric tube insertion in patients with thoracic esophageal cancer surgery. World J Surg Onc 19, 317 (2021). https://doi.org/10.1186/s12957-021-02428-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12957-021-02428-7

Keywords