Skip to main content

10 % fluorescein sodium vs 1 % isosulfan blue in breast sentinel lymph node biopsy

Abstract

Background

Sentinel lymph node biopsy (SLNB) is well accepted to be a standard procedure in breast cancer surgery with clinically negative lymph nodes. Isosulfan blue is the first dye approved by the USA Food and Drug Administration for the localization of the lymphatic system. Few alternative tracers have been investigated. In this study, we aimed to compare the differences between 10 % fluorescein sodium and 1 % isosulfan blue in breast sentinel lymph node biopsy and to investigate the feasibility of using 10 % fluorescein sodium as a new dye for breast sentinel lymph node biopsy.

Methods

A total of 30 New Zealand rabbits were randomly divided into the fluorescein sodium group and the isosulfan blue group (15 rabbits per group). Fluorescein sodium or isosulfan blue was injected subcutaneously into the second pair of mammary areolas.

Results

The average fading time of the second lymph nodes in the isosulfan blue group was significantly shorter than that in the fluorescein sodium group. Moreover, the detection rates of SLNs were higher in the fluorescein sodium group than in the isosulfan blue group. No significant differences between the fluorescein sodium group and isosulfan blue group were observed regarding the distances between the detected sentinel lymph nodes and second pair of mammary areolas, the distances between the second lymph nodes and second pair of mammary areolas, the number of detected sentinel lymph nodes and second lymph nodes, the average dyeing time of the sentinel and the second lymph nodes, and the average fading time of the second lymph nodes.

Conclusions

In summary, we first reported that fluorescein sodium is a potential new tracer for breast sentinel lymph node biopsy.

Background

Breast cancer is the most common carcinoma in females and the second leading cause of cancer death in women [1]. The sentinel lymph node (SLN) status, an accurate predictor of axillary lymph node status, has been shown to be one of the most important prognostic factors in breast cancer [2]., Sentinel lymph node biopsy (SLNB) is a safe and reliable technique that is well accepted as a standard procedure in breast cancer surgery with clinically negative lymph nodes [3].

Currently, different tracer materials have been reported in SLNB of breast cancer, such as blue dye, radioisotope, carbon nanoparticles, or a combination [4, 5]. However, there is no consensus regarding the optimal tracer materials for SLNB [6]. The detection rate of blue dye is lower than that of radioisotope despite its cost effectiveness and safety [4]. The application of radioisotope in SLNB is hampered by the risk of radiation exposure and poor quality of lymph vessel mapping [7, 8]. The use of carbon nanoparticles is limited by the high cost. Therefore, the development of new tracer materials for SLNB is still needed.

Fluorescein sodium (FS) is a fluorescent dye that is widely used in ophthalmic surgery and malignant brain tumor surgery [9, 10]. Ten percent FS, a widely available substance, is conventionally safe without any clearly associated adverse effects. Furthermore, FS was reported to be an effective tracer material for SLN mapping in colorectal tumors [11]. However, to our knowledge, the use of FS in SLNB of breast cancer has not been reported previously. In this study, we aimed to compare the usefulness of 10 % FS and 1 % isosulfan blue (commonly used blue dye) to investigate the feasibility of using 10 % FS in SLNB of breast cancer.

Methods

Animal experiments

Thirty female New Zealand White rabbits weighing between 2.0 and 2.5 kg were randomly divided into the FS group and isosulfan blue group (15 rabbits each group).

Solutions of 10 % FS (Santa Cruz Biotechnology, Dallas, TX, USA) and 1 % isosulfan blue (US Surgical Corp, North Haven, CT, USA) were prepared using sterile water for injection as the solvent. Rabbits were anesthetized with pentobarbital intravenously (15 mg/ml, 2 ml/kg, pentobarbital sodium; Sigma, St, Louis, MO, USA). After anesthesia, rabbits were positioned supine and the planned injection sites were clipped. The skin flaps were elevated from the second mammary glands and extended to fossa axillaris bilaterally. Careful blunt dissection was performed to avoid the injury of blood vessels and lymphatic vessels. Intradermal injection of 0.3 ml 10 % FS or 1 % isosulfan blue was made at the bilateral sites of the second mammary gland of rabbits in FS group or isosulfan blue group, respectively.

The operating room lights were adjusted to the dim mode, and a hand-held 485-nm wavelength blue light source (Model: LTS-RN9070; Ling Liang Vision, Shanghai, China) was used as exciting light for FS. Goggles with a blue light filter were equipped to search for the yellow-green FS-detected SLNs (Fig. 1). The FS-detected SLNs were defined as the first one to two fluorescent lymph nodes in the dark background. The FS-detected second lymph nodes were defined as the fluorescent lymph nodes receiving drainage from the FS-detected SLNs and connected with the fluorescent lymphatic vessels. On the other hand, the isosulfan blue-detected lymph nodes were observed under the operating room lights in the regular mode. The isosulfan blue-detected SLNs were defined as the first one to two blue-stained lymph nodes visible in the fossa axillaris area. The isosulfan blue-detected second lymph nodes were blue-stained lymph nodes that received drainage from the isosulfan blue-detected SLNs. The two tracers were compared for the average dyeing time of the sentinel and second lymph nodes, average fading time of the sentinel and second lymph nodes, detection rates, distances between the detected SLNs and second pair of mammary areolas, and distances between the second lymph nodes and second pair of mammary areolas, as well as the number of detected SLNs and second lymph nodes.

Fig. 1
figure 1

LTS-RN9070 blue light source system and goggle with blue light filter

After the observation of all of the data, animals were sacrificed with pentobarbital intravenously (325 mg/ml, 10 ml).

Statistical analysis

The numerical data were presented as the means ± standard deviation (SD), and p values were calculated by Student’s t test. Fisher’s exact test was used to compare the detection rates of SLNs between the two groups. All of the statistical analyses were carried out using STATA 11 (StataCorp LP, College Station, TX, USA). Differences with a p value less than 0.05 were considered statistically significant.

Results

General aspects

All rabbits in the FS group and isosulfan blue group were kept in the same cleaning cages and were fed with the same rabbit feed (corn 80 %, hay 10 %, bran 5 %, bone meal 3 %, salt 2 %, no autofluorescence ingredient was included). No significant differences were observed between the FS group and isosulfan blue group regarding weight, the distances between the detected sentinel lymph nodes and second pair of mammary areolas, or the distances between the second lymph nodes and second pair of mammary areolas (Table 1).

Table 1 General aspects of animals in two groups

Afferent lymphatic vessels stained by FS and isosulfan blue

The afferent lymphatic vessels stained by FS were easily visualized under florescent light even when they were covered by tissues (Figs. 2 and 3). However, the lymphatic vessels stained with isosulfan blue were faint and difficult to observe under incandescent or fluorescent light. The detection rate of afferent lymphatic vessels using FS was higher than that using isosulfan blue (100 vs 80 %, respectively) (Table 2).

Fig. 2
figure 2

Percutaneously observable FS signal in a lymphatic vessel. The second mammary glands are stained by FS (arrow head), and the afferent lymphatic vessel is stained by FS (arrow)

Fig. 3
figure 3

Lymphatic vessel and lymph node stained by FS

Table 2 Comparative analysis of various parameters between two groups

Comparison of FS and isosulfan blue in lymph node dissection

A mean of 1.36 SLNs per side and a mean of 0.88 of the second lymph nodes per side were identified in the FS group. By contrast, the average number of SLNs and second lymph nodes per side identified in the isosulfan blue group was 1.38 and 0.79, respectively. No significant differences were found between the two groups (Table 2).

There were no significant differences between the FS group and isosulfan blue group in the average dyeing time of the SLNs (142 vs 206 s) and second lymph nodes (502 vs 483 s, respectively). Furthermore, no significant differences were observed between the FS group and isosulfan blue group in the fading time of SLNs (4327 vs 3482 s, respectively). However, the fading time of the second lymph nodes was much longer in the FS group than in the isosulfan blue group.

The detection rates of SLNs in the FS group were each 100 %. By contrast, the detection rates of SLNs in the isosulfan blue group (80 %) were significantly lower than those in the FS group (p = 0.024). To further investigate the superiority of FS in SLN detection, we performed intradermal injection of 0.3 ml of 10 % FS into the second mammary gland of rabbits in which isosulfan blue was failed to detect the SLNs. All of the SLNs that could not be detected in the isosulfan blue group were successfully identified by the supplementary injection of FS.

Side effects

No side effects were observed in either the FS group or isosulfan blue group during the process of tracer injection and lymph node dissection.

Discussion

Isosulfan blue is the first dye to be approved by the USA Food and Drug Administration for the localization of the lymphatic system [12]. Although various tracer materials for SLNB have emerged in the past two decades, isosulfan blue is still accepted as one of the most effective tracers in SLNB because of the simplicity of its use and availability [11]. Despite the wide use of isosulfan blue in SLNB of breast cancer, isosulfan blue has been reported to cause erroneous pulse oximetry readings [13]. Furthermore, the relatively high cost of isosulfan blue has limited its popularization in developing countries.

FS was reported as an alternative tracer with some clear advantages in sentinel node mapping in colorectal tumors. In this study, 1 % isosulfan blue was used as a control tracer to compare the usefulness of FS with that of isosulfan blue and to evaluate the feasibility of using 10 % FS in SLNB of breast cancer.

Isosulfan blue is a reliable tracer material in lymphatic vessel identification during SLNB of breast cancer [14, 15]. However, the detection rate of afferent lymphatic vessels by isosulfan blue is only 80 % in our study. By contrast, all of the afferent lymphatic vessels were identified in the FS group. On the other hand, it may take a long time for surgeons to learn the blue dye method [16]. Our results have shown that the fluorescence in FS-stained lymphatic vessels and lymph nodes could easily penetrate the fur and tissues of rabbits and could be visualized percutaneously. Thus, FS-based SLNB is much easier to perform and requires a shorter learning curve than isosulfan blue.

In our study, the detection rate of SLNs was 80 % for isosulfan blue-guided SLNB, a finding that is consistent with that in other studies showing a detection rate ranging from 75 to 90 % with isosulfan blue dye [17, 18]. By contrast, the identification rate of SLNs in the FS group was 100 %.

Skip metastases are not very common, and the incidence has been reported to be 15 % for breast cancer [19]. However, the presence of skip metastasis and non-sentinel lymph node metastasis did affect the success of SLNB in breast cancer. Therefore, it is essential to evaluate the effectiveness of tracers in identifying second lymph nodes that are considered potential metastatic non-sentinel lymph nodes. In our study, there was no statistically significant difference in the average dyeing time and number of second lymph nodes in the FS group compared with those in the isosulfan blue group. Nevertheless, the fading time of second lymph nodes was much longer in the FS group than in the isosulfan blue group, potentially providing surgeons with additional time to identify the metastatic non-sentinel lymph nodes.

As a fluorescent dye, indocyanine green (ICG) has been regarded as a novel method in SLNB in breast cancer. The detection rate of using ICG was reported to be 80 %, which is slightly lower than that of FS [20]. Furthermore, the use of ICG is associated with high cost equipment [21]. Recently, a new non-radioactive method was developed, using superparamagnetic iron oxide (SPIO) nanoparticles as tracer and manual magnetometer as detector. This new method was reported to be non-inferiority compared to the combination of radioisotope and blue dye. However, the application of SPIO is limited by the high cost and the requirement of special plastic surgical material, while the usage of FS as tracer for SLNB is more economical (5 ml FS: 20 US dollar, goggle: 30 US dollar/pair, blue light source: 400 US dollar).

Conclusions

In summary, our study is the first report to compare the use of 10 % FS and 1 % isosulfan blue in SLN mapping of breast cancer. We found that it is feasible and safe to use FS in SLNB of breast cancer. Moreover, as a potential tracer, FS is superior to isosulfan blue regarding certain aspects of SLNB of breast cancer. However, our data are based on animal models; further studies are still required to evaluate the safety and feasibility of using FS in SLNB of breast cancer in patients.

Abbreviations

FS:

Fluorescein sodium

SLN:

Sentinel lymph node

SLNB:

Sentinel lymph node biopsy

References

  1. Siegel R, Naishadham D, Jemal A. Cancer statistics, 2013. CA Cancer J Clin. 2013;63:11–30.

    Article  PubMed  Google Scholar 

  2. Zavagno G, De Salvo GL, Scalco G, Bozza F, Barutta L, Del Bianco P, Renier M, Racano C, Carraro P, Nitti D, Trialists G. A randomized clinical trial on sentinel lymph node biopsy versus axillary lymph node dissection in breast cancer: results of the Sentinella/GIVOM trial. Ann Surg. 2008;247:207–13.

    Article  PubMed  Google Scholar 

  3. Mansel RE, Fallowfield L, Kissin M, Goyal A, Newcombe RG, Dixon JM, Yiangou C, Horgan K, Bundred N, Monypenny I, et al. Randomized multicenter trial of sentinel node biopsy versus standard axillary treatment in operable breast cancer: the ALMANAC trial. J Natl Cancer Inst. 2006;98:599–609.

    Article  PubMed  Google Scholar 

  4. Noguchi M, Inokuchi M, Zen Y. Complement of peritumoral and subareolar injection in breast cancer sentinel lymph node biopsy. J Surg Oncol. 2009;100:100–5.

    Article  PubMed  Google Scholar 

  5. Guo W, Zhang L, Ji J, Gao W, Liu J, Tong M. Breast cancer sentinel lymph node mapping using near-infrared guided indocyanine green in comparison with blue dye. Tumour Biol. 2014;35:3073–8.

    Article  CAS  PubMed  Google Scholar 

  6. Teal CB, Slocum JP, Akin EA. Evaluation of the benefit of using blue dye in addition to radioisotope for sentinel lymph node biopsy in patients with breast cancer. Breast J. 2005;11:391–3.

    Article  PubMed  Google Scholar 

  7. Stratmann SL, McCarty TM, Kuhn JA. Radiation safety with breast sentinel node biopsy. Am J Surg. 1999;178:454–7.

    Article  CAS  PubMed  Google Scholar 

  8. Sardi A, Spiegler E, Colandrea J, Frishberg D, Sing H, Regan P, Totoonchie A, Merchant D, Hochuli S, Setya V, Singer JA. The benefit of using two techniques for sentinel lymph node mapping in breast cancer. Am Surg. 2002;68:24–8.

    PubMed  Google Scholar 

  9. Rabb MF, Burton TC, Schatz H, Yannuzzi LA. Fluorescein angiography of the fundus: a schematic approach to interpretation. Surv Ophthalmol. 1978;22:387–403.

    Article  CAS  PubMed  Google Scholar 

  10. Schebesch KM, Proescholdt M, Hohne J, Hohenberger C, Hansen E, Riemenschneider MJ, Ullrich W, Doenitz C, Schlaier J, Lange M, Brawanski A. Sodium fluorescein-guided resection under the YELLOW 560 nm surgical microscope filter in malignant brain tumor surgery—a feasibility study. Acta Neurochir (Wien). 2013;155:693–9.

    Article  Google Scholar 

  11. Dan AG, Saha S, Monson KM, Wiese D, Schochet E, Barber KR, Ganatra B, Desai D, Kaushal S. 1 % lymphazurin vs 10 % fluorescein for sentinel node mapping in colorectal tumors. Arch Surg. 2004;139:1180–4.

    Article  CAS  PubMed  Google Scholar 

  12. Longnecker SM, Guzzardo MM, Van Voris LP. Life-threatening anaphylaxis following subcutaneous administration of isosulfan blue 1 %. Clin Pharm. 1985;4:219–21.

    CAS  PubMed  Google Scholar 

  13. Coleman RL, Whitten CW, O’Boyle J, Sidhu B. Unexplained decrease in measured oxygen saturation by pulse oximetry following injection of Lymphazurin 1 % (isosulfan blue) during a lymphatic mapping procedure. J Surg Oncol. 1999;70:126–9.

    Article  CAS  PubMed  Google Scholar 

  14. Kern KA. Sentinel lymph node mapping in breast cancer using subareolar injection of blue dye. J Am Coll Surg. 1999;189:539–45.

    Article  CAS  PubMed  Google Scholar 

  15. Wang M, Zhou W, Zhao Y, Xia T, Zha X, Ding Q, Liu X, Zhao Y, Ling L, Chen L, Wang S. A novel finding of sentinel lymphatic channels in early stage breast cancer patients: which may influence detection rate and false-negative rate of sentinel lymph node biopsy. PLoS ONE. 2012;7:e51226.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  16. Sanidas EE, de Bree E, Tsiftsis DD. How many cases are enough for accreditation in sentinel lymph node biopsy in breast cancer? Am J Surg. 2003;185:202–10.

    Article  PubMed  Google Scholar 

  17. O’Hea BJ, Hill AD, El-Shirbiny AM, Yeh SD, Rosen PP, Coit DG, Borgen PI, Cody 3rd HS. Sentinel lymph node biopsy in breast cancer: initial experience at Memorial Sloan-Kettering Cancer Center. J Am Coll Surg. 1998;186:423–7.

    Article  PubMed  Google Scholar 

  18. Simmons RM, Smith SM, Osborne MP. Methylene blue dye as an alternative to isosulfan blue dye for sentinel lymph node localization. Breast J. 2001;7:181–3.

    Article  CAS  PubMed  Google Scholar 

  19. Reintgen D, Cruse CW, Wells K, Berman C, Fenske N, Glass F, Schroer K, Heller R, Ross M, Lyman G, et al. The orderly progression of melanoma nodal metastases. Ann Surg. 1994;220:759–67.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  20. Ueno H, Hihara J, Shimizu K, Osaki A, Yamashita Y, Yoshida K, Toge T. Experimental study on fluorescent microspheres as a tracer for sentinel node detection. Anticancer Res. 2005;25:821–5.

    PubMed  Google Scholar 

  21. He K, Chi C, Kou D, Huang W, Wu J, Wang Y, He L, Ye J, Mao Y, Zhang GJ, et al. Comparison between the indocyanine green fluorescence and blue dye methods for sentinel lymph node biopsy using novel fluorescence image-guided resection equipment in different types of hospitals. Transl Res. 2016;16:30115–23.

    Google Scholar 

Download references

Acknowledgements

Not applicable

Funding

This work was supported in part by the National Natural Science Foundation of China (81572607, 81572595, 81572602, 81502299, 81602321, and 81502286), the Natural Science Foundation of Jiangsu Province (BK2010581, BK2011853, BK2011855, and BK20141023), the Program for Development of Innovative Research Team in the First Affiliated Hospital of NJMU (IRT-008), a project funded by the Priority Academic Program Development (PAPD) of Jiangsu higher education institutions, and the Natural Science Foundation of Inner Mongolia (010017).

Availability of data and materials

All data generated or analyzed during this study are included in this published article.

Authors’ contributions

RLD, LZ, and WS designed the research and drafted the manuscript. RLD, LZ, LMD, WL, and SXL attended the animal work. WS modified the manuscript. All authors read and approved the final manuscript.

Competing interests

The authors declare that they have no competing interests.

Consent for publication

Not applicable.

Ethics approval

All of the animal protocols were approved by the Institutional Animal Care and Use Committee of Nanjing Medical University. All of the animal experiments were monitored by the Department of Laboratory Animal Resources of Nanjing Medical University.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Shui Wang.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ren, L., Liu, Z., Liang, M. et al. 10 % fluorescein sodium vs 1 % isosulfan blue in breast sentinel lymph node biopsy. World J Surg Onc 14, 280 (2016). https://doi.org/10.1186/s12957-016-1031-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12957-016-1031-1

Keywords