Table 2 Diagnostic accuracies of CT and MRI (n = 68)

From: Diagnostic accuracy of contrast-enhanced computed tomography and contrast-enhanced magnetic resonance imaging of small renal masses in real practice: sensitivity and specificity according to subjective radiologic interpretation

Radiologic interpretation

“4 (probably solid RCC) and 5 (definitely solid RCC)”

“3 (indeterminate RCC)”

Total

CT

33 (48.5)

21 (30.8)

54 (79.41)

MRI

46 (67.6)

14 (20.58)

60 (88.23)

Radiologic interpretation

Sensitivity

Specificity

AUC

SEa

95 % CIb

CT

79.7

44.4

0.621

0.0917

0.495 to 0.736

MRI

88.1

33.3

0.607

0.0860

0.481 to 0.724