Skip to main content

Table 4 Clinic outcomes of stenting (n/N, %)

From: Self-expanding metal stent insertion by colorectal surgeons using a two-person approach colonoscopy without fluoroscopic monitoring in the management of acute colorectal obstruction: a 14-year experience

Characteristic

Palliative stents (n = 124)

BTS (n = 277)

Others (n = 33)

Recurrent tumor (n = 10)

Benign diseases (n = 10)

Extra-luminal compression (n = 13)

Technique success rate

121, 97.6%

274, 98.9%

10, 100%

10, 100%

13, 100%

Clinic success rate

118, 95.2%

261, 94.2%

10, 100%

10, 100%

13, 100%

Complication rate

4, 3.2%

13, 4.7%

0, 0%

2, 20%

0, 0%

ES required

6, 4.8%

15, 5.4%

0, 0%

0, 0%

0, 0%

Subsequent surgery required

7, 5.6%

258, 93.1%

2, 20%

5, 50%

2, 15.4%

Re-stenting

2, 1.6%

2, 0.7%

0, 0%

0, 0%

0, 0%