Skip to main content

SUVmax of 18F-FDG PET/CT in the differential diagnosis of benign and malignant thyroid nodules according to tumor volume

Abstract

Background

The aim of this study was to investigate whether the maximum standardized uptake value (SUVmax) measured on fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) could be used as the primary means of differential diagnosis of thyroid nodules when tumor volume is assessed.

Methods

We studied 192 patients who underwent preoperative 18F-FDG PET/CT followed by thyroidectomy. We evaluated the correlation between the volume of thyroid nodules, 18F-FDG uptake on visual analysis, and the mean SUVmax measured on 18F-FDG PET/CT.

Results

When stratified by tumor volume, the mean SUVmax was higher in malignant than in benign nodules in nodules ≥1 cm3 (p < 0.001). However, it did not differ between benign and malignant nodules smaller than 1 cm3. At a cut-off value of SUVmax of 6, the respective sensitivities of 18F-FDG PET/CT, ultrasonography, and fine needle aspiration cytology were 60.8, 96.4, and 99.1 %, and the respective specificities were 95.9, 98.2, and 96.8 %.

Conclusions

18F-FDG PET/CT is limited as a primary modality in the differential diagnosis of benign and malignant thyroid nodules because of its low sensitivity.

Background

Unlike normal tissue, malignant tumors are characterized by increased glycolysis, which leads to elevated glucose uptake. Fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) makes use of this to aid the diagnosis and staging of various human malignancies.

In recent years, 18F-FDG PET/CT has become widely used to diagnose thyroid cancer; it is especially useful in identifying sites of recurrence in patients with elevated serum thyroglobulin and negative whole body radioactive iodine scans after thyroidectomy for differentiated thyroid carcinoma [13]. 18F-FDG PET/CT also has potential advantages in the detection of distant metastasis or synchronous secondary tumor although its cost-effectiveness is not determined. However, the role of 18F-FDG PET/CT in the differential diagnosis of benign and malignant thyroid nodules is not yet well-established in clinical practice because some benign thyroid nodules show high 18F-FDG uptake, while some malignant nodules are not visualized at all. Consequently, there is a paucity of data regarding the role of 18F-FDG PET/CT in the differential diagnosis of thyroid nodules; the few studies that exist were conducted in small series of patients [46] or in patients whose nodules were identified incidentally during routine health checks [79]. In addition, while these studies estimated the mean maximum standardized uptake value (SUVmax) of 18F-FDG, they failed to consider the effect of nodule size. Other studies have enrolled patients with metastatic thyroid cancer or those with diffuse thyroid uptake of 18F-FDG.

Our aim in the present study was to establish whether the SUVmax measured on 18F-FDG PET/CT could be a primary modality in the differential diagnosis of benign and malignant thyroid nodules according to tumor volume.

Methods

Patients

We retrospectively studied 192 patients who underwent thyroidectomy for thyroid nodules and received a preoperative 18F-FDG PET/CT scan out of about 3500 patients who were diagnosed with thyroid nodule in our institute between January 2007 and December 2009. Of the tumors, 152 were malignant and 40 benign. Among the malignant cases, there were 146 papillary carcinomas, 3 follicular carcinomas, and 3 anaplastic carcinomas. The benign cases comprised 38 nodular hyperplasias and 2 follicular adenomas. Of the patients, 23 (15 %) were men and 129 (85 %) women. The mean age was 56 years, and all patients had normal thyroid function. The study protocol was approved by the Institutional Review Board of Hanyang University Hospital.

In this study, 141 patients with malignant nodule underwent 18F-FDG PET/CT scan to evaluate distant or regional metastasis after diagnosis of thyroid cancer by fine needle aspiration cytology (FNAC) according to the patient’s request or the recommendation of the doctors. Thirty-two patients with incidentally found benign and malignant nodule underwent 18F-FDG PET/CT scan for the purpose of routine health examination or evaluation of metastasis from other malignancy, and 19 patients of study group underwent 18F-FDG PET/CT for research purposes after submitting their written informed consent, especially in patients with follicular neoplasm or indeterminate cases on FNAC.

Exclusion criteria were recurrent thyroid cancer, diffuse 18F-FDG uptake by the thyroid that could not be differentiated from thyroid nodule on 18F-FDG PET/CT, and a history of thyroid surgery, or radiotherapy in the head and neck region for other diseases.

Patients with benign nodules underwent thyroidectomy: (1) for cosmetic purposes, (2) at their request, (3) if malignancy was suspected on ultrasonography (US), or (4) if their FNAC results were classified as inadequate or indeterminate.

Thyroid US and ultrasound-guided FNAC were performed by an experienced board-certified specialist in all cases. The FNAC results were categorized as (1) inadequate, (2) benign, (3) indeterminate (e.g., follicular neoplasm or atypia), (4) suspected malignancy, or (5) malignancy. In cases of microcalcification, irregular margins, marked hupoechogenity, or a taller-than-wide shape on US, the nodules were interpreted as malignant. Nodule diameter on US was used to calculate nodule volume. If there were multiple nodules on US, we measured a single nodule that was also examined by FNAC.

18F-FDG PET/CT

Whole body PET/CT images were acquired using a dedicated PET/CT system (Biograph 6, Siemens Medical Systems, Knoxville, TN, USA). Hard exercise was prohibited for several days, and the patients fasted for at least 6 h prior to the scan. Blood glucose levels were tested to confirm they were below 200 mg/dL. After an intravenous injection of 18F-FDG (0.21 mCi/kg), the patients were asked to wait for 1 h in a dimly lit room and encouraged to drink 1 L of water. A CT scan (80 mA and 140 kVp) was performed to correct attenuation prior to the PET scan. CT scanning was performed in 5-mm sections from the base of the skull to the proximal thigh; the images were reconstructed using a 512 × 512 matrix and a 50-cm field of view. PET scans were obtained from the proximal thigh to the base of the skull (six to seven bed positions, 2 min 30 s per each position), and the images were reconstructed with a 168 × 168 matrix, using the ordered subset expectation maximum iterative reconstruction algorithm, a 5-mm Gaussian filter, and a 50-cm field of view.

18F-FDG uptake by thyroid nodules was evaluated by visual analysis using the naked eye and quantitative measurement using SUVmax. If there is any focal increased uptake lesion detected in anterior neck on maximum intensity projection images by visual analysis, the uptake of thyroid nodule was verified by thorough examination of the axial PET/CT images by two nuclear medicine physicians. Then, SUVmax was measured for each thyroid nodule using volume of interest (VOI). SUV was calculated as follows: SUV = [FDG activity concentration (Bq/mL)] × [total lean body mass (kg)]/[injected FDG activity (Bq)].

Statistical analysis

Statistical analyses were carried out with SPSS 17.0 (SPSS Inc., Chicago, IL, USA). We compared the uptake of 18F-FDG analyzed visually and SUVmax determined on 18F-FDG PET/CT between malignant and benign thyroid nodules. The same comparisons were made when the nodules were stratified by volume using a cut-off volume of 1 cm3. An independent Student t-test was performed to identify differences in SUVmax between the malignant and benign thyroid nodules. Pearson’s correlation coefficients were calculated to determine the correlation between nodule volume and the SUVmax.

Results

Differences in volume and SUVmax between malignant and benign nodules

The mean volumes of the malignant and benign nodules were not significantly different (11.63 ± 7.27 mL vs. 10.98 ± 4.56 mL; p = 0.968). On the other hand, the mean SUVmax was significantly higher in malignant than in benign nodules (5.11 ± 0.49 vs. 2.32 ± 0.25; p < 0.001). Among the malignant cases, the mean SUVmax was 4.80 ± 0.46 for papillary carcinoma, 17.66 ± 7.65 for follicular carcinoma, and 7.72 ± 3.44 for anaplastic carcinoma. In the benign cases, it was 2.45 ± 0.27 for nodular hyperplasia and 1.05 ± 1.05 for follicular adenoma.

Differences in 18F-FDG uptake on visual analysis and SUVmax between malignant and benign nodules stratified by nodule volume

The differences between malignant and benign nodules in terms of visual 18F-FDG uptake and SUVmax, stratified by nodule volume, are shown in Tables 1 and 2. In nodules smaller than 1 cm3 (98 cases), 18F-FDG uptake on visual analysis was not different between the malignant and benign cases (p = 0.572). However, in nodules ≥1 cm3 (94 cases), it was significantly higher in malignant than in benign nodules (all patients with malignant nodules vs. 79.2 % of patients with benign nodules; p < 0.001) (Table 1). In nodules <1 cm3, mean SUVmax was 1.90 ± 0.21 in the malignant cases and 2.15 ± 0.42 in the benign cases (p = 0.630). However, it was significantly higher in malignant nodules with volumes ≥1 cm3 (8.88 ± 0.82 for malignant vs. 2.55 ± 0.33 for benign nodules, p < 0.001) (Table 2).

Table 1 18F-FDG uptake by visual analysis of 18F-FDG PET/CT images in malignant and benign thyroid nodules according to nodule volume
Table 2 Mean SUVmax of malignant and benign nodules according to nodule volume

Correlation between nodule volume and SUVmax

There was no significant correlation between the volumes of all thyroid nodules and mean SUVmax (Pearson’s correlation coefficient, r = 0.149). Likewise, there was no significant correlation between the volume of malignant nodules only and mean SUVmax (r = 0.151). When stratified by volume, a weak correlation (r = 0.452) with SUVmax was observed in the case of small (<1 cm3) malignant nodules, but not in the case of larger (≥1 cm3) malignant nodules (r = 0.076).

Diagnostic accuracy of 18F-FDG PET/CT, US, and FNAC

In the case of volumes ≥1 cm3, a receiver operating characteristic (ROC) curve analysis determined the optimal value of SUVmax for differential diagnosis between benign and malignant thyroid nodules (Fig. 1). The diagnostic power of 18F-FDG PET/CT was the highest at SUVmax = 6: at that value, it had 60.8 % sensitivity, 96.8 % specificity, a positive predictive value of 97.7 %, a negative predictive value of 48.4 %, and 70.2 % diagnostic accuracy.

Fig. 1
figure 1

Receiver operating characteristic (ROC) curve of SUVmax. The diagnostic power of 18F-FDG PET/CT is the highest at SUVmax = 6

We compared the results of thyroid US, FNAC, and 18F-FDG PET/CT at that cut-off value. Their respective sensitivities were 96.4, 99.1, and 60.8 %, and respective specificities were 95.9, 98.2, and 96.8 %. Similarly, their respective positive predictive values were 98.9, 99.4, and 97.7 %, and respective negative predictive values were 86.8, 95.2, and 48.4 %. Diagnostic accuracy was 97.3 % for thyroid US, 98.8 % for FNAC, and 70.2 % for 18F-FDG PET/CT.

Diagnostic accuracy of 18F-FDG PET/CT in cases undiagnosed by FNAC

FNAC diagnosed 151 cases of malignancy or suspected malignancy, 35 benign cases, 4 cases classified as indeterminate, and 2 as inadequate. Of the 151 supposed malignancies, 1 was found to be benign after thyroidectomy. Of the four indeterminate cases, two were confirmed as follicular carcinomas and two as follicular adenomas (Figs. 2 and 3). The cases classified as inadequate were found to be nodular hyperplasia (Table 3).

Fig. 2
figure 2

Images of follicular adenoma. a On ultrasonography, there is an 8-cm, markedly hypoechoic nodule. b Mildly increased 18F-FDG uptake in the left lobe on 18F-FDG PET/CT (SUVmax = 2.10)

Fig. 3
figure 3

Images of follicular carcinoma. a On ultrasonography, there is a 1.7-cm, hypoechoic nodule. b Focal, intense 18F-FDG uptake in the left isthmic nodule on 18F-FDG PET/CT (SUVmax = 11.97)

Table 3 Pathology results and SUVmax on 18F-FDG PET/CT in cases that were inconclusive on fine needle aspiration cytology

When the six patients with indeterminate or inadequate findings on FNAC were examined by 18F-FDG PET/CT (with a cut-off SUVmax = 6), the method had 100 % sensitivity and specificity, 0 % false positives and false negatives, positive and negative predictive values of 100 %, and 100 % diagnostic accuracy.

Discussion

In our study, the mean SUVmax was on the whole significantly higher in malignant than in benign thyroid nodules (p < 0.001). However, when the nodules were stratified by volume, we observed no significant differences in 18F-FDG uptake on visual analysis and in mean SUVmax between the malignant and benign nodules when the nodules were below 1 cm3. This might be due to the partial-volume effect, i.e., underestimation of small volumes. The resolution of 18F-FDG PET/CT is estimated at approximately 6 mm3 [10]. When 18F-FDG PET/CT is performed on smaller lesions, the adjacent normal tissue that does not show increased uptake is also present in the visual field, and this may lead to inaccurate assessment of FDG uptake. Hence, in this study, we evaluated the diagnostic accuracy of 18F-FDG PET/CT only in nodules with a volume ≥1 cm3 except for those nodules <1 cm3 in which neither visual analysis of uptake nor mean SUVmax had any power to differentiate between malignant and benign nodules.

As a tool in the differential diagnosis of benign and malignant thyroid nodules, thyroid US has been shown to have sensitivity of 30–75 %, specificity of 80–95 %, positive predictive value of 15–94 %, negative predictive value of 70–80 %, and diagnostic accuracy of approximately 75 % [11, 12]. By comparison, the sensitivity and specificity of FNAC have been estimated at approximately 85–90 % and 85–97 %, respectively, although these values may vary depending on the examiner’s technical skills [13, 14]. In our study, both thyroid US and FNAC had a higher diagnostic accuracy than suggested in the previous reports (the corresponding values for US in our study were 96.4, 95.9, 98.9, 86.8, and 97.3 %; and for FNAC: 99.1, 98.2, 99.4, 95.2, and 98.8 %). One of the contributing factors could be our study criteria, which excluded patients with negative findings on FNAC despite having intermediate findings or a suspected malignancy on US.

In the current study, the diagnostic ability of 18F-FDG PET/CT to differentiate benign and malignant thyroid nodules was lower than that of US or FNAC, even in larger (≥1 cm3) nodules. This implies that 18F-FDG PET/CT is less likely to be a primary modality in the differential diagnosis of all thyroid nodules. Furthermore, the role of 18F-FDG PET/CT as the primary modality in the differential diagnosis of thyroid carcinoma may be limited at the present time because the small thyroid cancer with a volume of <1 cm3 is common, and the diagnostic accuracy of 18F-FDG PET/CT is especially low in those cases. In addition, considering cost-effectiveness, 18F-FDG PET/CT is not recommended routinely.

However, the SUVmax of 18F-FDG PET/CT might be useful in the differential diagnosis of thyroid nodule detected incidentally by 18F-FDG PET/CT scan which was performed for the purpose of routine health examination or evaluation of metastasis from other malignancy. Our findings suggest that malignancy can be suspected when nodules ≥1 cm3 show FDG uptake on visual analysis of PET/CT images, because all the malignant thyroid nodules with a volume of ≥1 cm3 showed the uptake on visual analysis. In particular, there is a very high probability that thyroid nodules with a volume of ≥1 cm3 and SUVmax of >6 on 18F-FDG PET/CT are thyroid carcinoma because of a higher specificity of 96.8 % and a positive predictive value of 97.7 %.

According to reports, differential diagnosis by FNAC can be difficult in approximately 20 % of thyroid nodules, particularly in the case of non-diagnostic or unsatisfactory samples, follicular lesions of undetermined significance, or follicular neoplasms [15]. The diagnostic power of 18F-FDG PET/CT in such cases is still controversial [1619]. Here, we evaluated the role of 18F-FDG PET/CT in six patients whose preoperative ultrasound-guided FNAC findings were not conclusively malignant or benign. In these patients, the sensitivity and specificity of 18F-FDG PET/CT were 100 %, indicating that it might be a useful modality in cases undiagnosed by FNAC. However, before these findings can be considered conclusive, they should be verified in a larger sample of patients.

Inevitably, this study has some limitations. The patients were not randomized, and there was selection bias. We included only those who underwent thyroidectomy and 18F-FDG PET/CT for benign or malignant nodules. We excluded any benign or indeterminate cases where thyroidectomy was not indicated and those cases in which 18F-FDG PET/CT was not performed.

Conclusions

18F-FDG PET/CT is limited as a primary modality in the differential diagnosis of benign and malignant thyroid nodules because of its low sensitivity. However, malignancy can be suspected when a visual analysis of 18F-FDG PET/CT images shows increased FDG uptake in nodules with volumes ≥1 cm3. In addition, if SUVmax is greater than 6 in nodules ≥1 cm3, the probability of malignancy is very high.

Abbreviations

18F-FDG PET/CT:

fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography

FNAC:

fine needle aspiration cytology

SUVmax:

maximum standardized uptake value

US:

ultrasonography

References

  1. Feine U, Lietzenmayer R, Hanke JP, Held J, Wohrle H, Muller-Schauenburg W. Fluorine-18-FDG and iodine-131-iodide uptake in thyroid cancer. J Nucl Med. 1996;37:1468–72.

    CAS  PubMed  Google Scholar 

  2. Wang W, Macapinlac H, Larson SM, Yeh SD, Akhurst T, Finn RD, et al. [18F]2-Fluoro-2-deoxy-D glucose positron emission tomography localizes residual thyroid cancer in patients with negative diagnostic (131)I whole body scans and elevated serum thyroglobulin levels. J Clin Endocrinol Metab. 1999;84:2291–302.

    Article  CAS  PubMed  Google Scholar 

  3. Dietlein M, Scheidhauer K, Voth E, Theissen P, Schicha H. Fluorine-18 fluorodeoxyglucose positron emission tomography and iodine-131 whole-body scintigraphy in the follow up of differentiated thyroid cancer. Eur J Nucl Med. 1997;24:1342–8.

    Article  CAS  PubMed  Google Scholar 

  4. Kresnik E, Gallowitsch HJ, Mikosch P, Stettner H, Igerc I, Gomez I, et al. Fluorine-18 fluorodeoxyglucose positron emission tomography in the preoperative assessment of thyroid nodules in an endemic goiter area. Surgery. 2003;133:294–9.

    Article  PubMed  Google Scholar 

  5. Bloom AD, Adler LP, Shuck JM. Determination of malignancy of thyroid nodules with positron emission tomography. Surgery. 1993;114:728–34.

    CAS  PubMed  Google Scholar 

  6. Mitchell JC, Grant F, Evenson AR, Parker JA, Hasselgren PO, Parangi S. Preoperative evaluation of thyroid nodules with 18FDG-PET/CT. Surgery. 2005;138:1166–74.

    Article  PubMed  Google Scholar 

  7. Cohen MS, Arslan N, Dehdashti F, Doherty GM, Lairmore TC, Brunt LM, et al. Risk of malignancy in thyroid incidentalomas identified by fluorodeoxyglucose-positron emission tomography. Surgery. 2001;130:941–6.

    Article  CAS  PubMed  Google Scholar 

  8. Kang KW, Kim SK, Kang HS, Lee ES, Sim JS, Lee IG, et al. Prevalence and risk of cancer of focal thyroid incidentaloma identified by 18-F-fluorodeoxyglucose positron emission tomography for metastasis evaluation and cancer screening in healthy subjects. J Clin Endocrinol Metab. 2003;88:4100–4.

    Article  CAS  PubMed  Google Scholar 

  9. Choi JY, Lee KS, Kim HJ, Shim YM, Kwon OJ, Park K, et al. Focal thyroid lesions incidentally identified by integrated 18F-FDG PET/CT: clinical significance and improved characterization. J Nucl Med. 2006;47:609–15.

    PubMed  Google Scholar 

  10. Hoffman EJ, Huang SC, Phelps ME. Quantitation in positron emission computed tomography: 1. Effect of object size. J Comput Assist Tomogr. 1979;3:299–308.

    Article  CAS  PubMed  Google Scholar 

  11. Frates MC, Benson CB, Charboneau JW, Cibas ES, Clark OH, Coleman BG, et al. Management of thyroid nodules detected at US: society of radiologists in ultrasound consensus conference statement. Radiology. 2005;237:794–800.

    Article  PubMed  Google Scholar 

  12. Kim EK, Park CS, Chung WY, Oh KK, Kim DI, Lee JT, et al. New sonographic criteria for recommending fine-needle aspiration biopsy of nonpalpable solid nodules of the thyroid. AJR. 2002;178:687–91.

    Article  PubMed  Google Scholar 

  13. Regina CM, Gharib H. Continuing controversies in the management of thyroid nodules. Ann Intern Med. 2005;142:926–31.

    Article  Google Scholar 

  14. Gardner HAR, Ducatman BS, Wang HH. Predictive value of fine-needle aspiration of the thyroid in the classification of follicular lesions. Cancer. 1993;71:2598–603.

    Article  CAS  PubMed  Google Scholar 

  15. Cibas ES, Ali SZNCI, Thyroid FNA. State of the Science Conference 2009: the Bethesda system for reporting thyroid cytopathology. Am J Clin Pathol. 2009;132:658–65.

    Article  PubMed  Google Scholar 

  16. Kim JM, Ryu JS, Kim TY, Kim WB, Kwon GY, Gong G, et al. 18F-fluorodeoxyglucose positron emission tomography does not predict malignancy in thyroid nodules cytologically diagnosed as follicular neoplasm. J Clin Endocrinol Metab. 2007;92:1630–4.

    Article  CAS  PubMed  Google Scholar 

  17. Sebastianes FM, Cerci JJ, Zanoni PH, Soares Jr J, Chibana LK, Tomimori EK, et al. Role of 18F-fluorodeoxyglucose positron emission tomography in preoperative assessment of cytologically indeterminate thyroid nodules. J Clin Endocrinol Metab. 2007;92:4485–8.

    Article  CAS  PubMed  Google Scholar 

  18. Traugott AL, Dehdashti F, Trinkaus K, Cohen M, Fialkowski E, Quayle F, et al. Exclusion of malignancy in thyroid nodules with indeterminate fine-needle aspiration cytology after negative 18F-fluorodeoxyglucose positron emission tomography: interim analysis. World J Surg. 2010;34:1247–53.

    Article  PubMed Central  PubMed  Google Scholar 

  19. Deandreis D, Al Ghuzlan A, Auperin A, Vielh P, Caillou B, Chami L, et al. Is 18F-fluorodeoxyglucose-PET/CT useful for the presurgical characterization of thyroid nodules with indeterminate fine needle aspiration cytology? Thyroid. 2012;22:165–72.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

No acknowledgements to make.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Kyung Tae.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

KT and THK designed the study. THK, YBJ, CMS, JYK, YYC, and JSP participated in acquisition of data and interpretation of data. YBJ and CMS performed statistical analysis. THK wrote the draft. KT, YYC, and JSP revised the manuscript. All authors read and approved the final manuscript.

Rights and permissions

Open Access  This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.

The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.

To view a copy of this licence, visit https://creativecommons.org/licenses/by/4.0/.

The Creative Commons Public Domain Dedication waiver (https://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kim, T.H., Ji, Y.B., Song, C.M. et al. SUVmax of 18F-FDG PET/CT in the differential diagnosis of benign and malignant thyroid nodules according to tumor volume. World J Surg Onc 13, 217 (2015). https://doi.org/10.1186/s12957-015-0635-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12957-015-0635-1

Keywords